Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS
The Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS (899-380-0153) is a high-capacity, transformer-based power backup solution designed for commercial IT infrastructure, server rooms, networking equipment and critical electronic applications.
Featuring 15KVA/12000W rated capacity, DSP-controlled IGBT inverter technology, a 0.8 output power factor, an inbuilt output isolation transformer and a 20A inbuilt battery charger, this Online UPS delivers reliable pure sine wave power with three-phase input and single-phase output.
Product Enquiry
Interested in this product? Fill out the form below.
Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS – Advanced Transformer-Based Power Backup
The Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS is a high-capacity power backup solution designed for professional IT infrastructure, commercial facilities and compatible critical electronic equipment. Featuring advanced Digital Signal Processing (DSP) technology, an IGBT-based inverter, a built-in output isolation transformer and a 0.8 output power factor, this UPS delivers dependable power protection in demanding electrical environments.
With a rated capacity of 15KVA/12000W, a 360V DC external battery system, a 20A inbuilt charger and smart LCD monitoring, the Microtek iMAXX Series combines reliable power conversion with flexible battery configuration and professional management features.
Manufactured by Microtek, this Online UPS is designed for installations requiring three-phase input and single-phase output (3:1).
True Online UPS Technology with DSP-Controlled IGBT Inverter
The Microtek 15KVA iMAXX Online UPS uses low-frequency transformer-based online power conversion with DSP-controlled IGBT inverter technology.
The UPS continuously supplies the protected load through its inverter during normal operation, helping maintain regulated AC output.
Incoming electrical power is processed by the UPS power conversion system before being delivered to connected equipment.
When incoming mains power becomes unavailable, a compatible external battery bank continues supplying energy to the inverter.
Microtek specifies zero transfer time from normal online operation to battery mode, helping minimize interruptions to properly connected equipment.
This technology is particularly relevant to computing systems, network infrastructure and business electronics where sudden power failures could disrupt critical operations.
Three-Phase Input and Single-Phase Output
The Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS features a 3:1 electrical configuration.
It accepts a suitable three-phase electrical supply and delivers regulated single-phase output to compatible connected equipment.
The manufacturer specifies nominal input voltages of 380V, 400V and 415V AC in a three-phase system.
Its default single-phase output voltage is 230V AC, with selectable 208V and 220V settings.
This configuration is suitable for commercial installations where a three-phase power distribution system is available, but protected single-phase output is required.
Customers should not confuse this model with a three-phase input, three-phase output UPS.
Electrical distribution, wiring, load calculations and circuit protection should be planned by a qualified electrical professional.
15KVA/12000W Capacity with 0.8 Output Power Factor
The Microtek iMAXX 15KVA Online UPS offers a rated capacity of 15000VA/12000W.
Its 0.8 output power factor provides 12000 watts of rated active output capacity.
This allows the UPS to support appropriately sized professional computing equipment, commercial electronics and other compatible critical loads.
Before installation, the total connected equipment load should be calculated carefully.
The calculation should include continuous consumption, expected operating peaks, equipment starting requirements and suitable headroom.
Maintaining adequate operating headroom can help reduce overload conditions and improve the reliability of the installation.
The connected equipment must remain within the UPS’s electrical and output capacity limits.
Inbuilt Output Isolation Transformer
One of the most important features of the Microtek 15KVA/360V iMAXX Online UPS is its built-in output isolation transformer.
The transformer provides galvanic electrical isolation in the supported output configuration.
This design can help reduce certain types of electrical interference and common-mode noise affecting sensitive electronic equipment.
The transformer is integrated into the UPS cabinet, allowing organizations to use a transformer-based power backup system without specifying a separate output isolation transformer where the built-in arrangement meets application requirements.
However, electrical isolation does not eliminate the need for proper grounding, circuit protection and safe installation.
Specialized industrial and laboratory equipment should be assessed for compatibility before connection.
360V DC External Battery System with Adjustable Battery Quantity
The Microtek iMAXX 15KVA UPS uses a 360V DC external battery system in its standard configuration.
The default setup requires 30 compatible 12V batteries connected in series.
According to Microtek’s technical documentation, the UPS supports adjustable battery configurations of 29, 30, 31 and 32 batteries.
These configurations correspond to nominal battery-bank voltages of 348V, 360V, 372V and 384V DC.
The battery quantity and UPS charging settings must be configured correctly for the chosen installation.
The manufacturer lists compatible lead-acid, tubular and sealed maintenance-free battery types.
Actual backup duration depends on installed battery capacity, connected load, battery condition, ambient temperature and system efficiency.
External battery racks, DC cables, battery breakers and other installation accessories should be selected as part of the complete electrical design.
20 Amp Inbuilt Battery Charger
The Microtek 15KVA/360V iMAXX Online UPS includes an inbuilt battery charging system with 20A charging capability.
The manufacturer identifies this charging capacity as a feature of its 360V iMAXX models.
The older technical table lists a default charging-current setting of 5A, with available charging current dependent on the manufacturer’s operating conditions.
Customers should therefore distinguish the 20A charger capacity from the charger’s configured operating current.
The correct charging arrangement depends on battery capacity, battery specifications, electrical load and UPS configuration.
For a high-voltage external battery system, charging settings should only be adjusted according to approved manufacturer instructions.
This model should not automatically be assigned the additional 4A charger option listed for certain 192V iMAXX models.
Pure Sine Wave Output with Stable Voltage Regulation
The Microtek iMAXX 15KVA Online UPS provides pure sine wave output during battery operation.
Pure sine wave power supports reliable operation of many compatible electronic power supplies and professional IT devices.
The manufacturer specifies a default output of 230V AC with approximately ±1% regulation.
Output voltage can be configured to supported 208V, 220V or 230V settings.
Its specified output harmonic distortion is below 2% for linear loads and below 5% for non-linear loads.
The UPS provides a battery-mode output frequency of approximately 50Hz ±0.1Hz.
These features help maintain consistent AC output quality for suitably designed electrical installations.
Parallel Redundancy for Critical Power Applications
The Microtek 15KVA/360V iMAXX 3-Phase Input Online UPS supports manufacturer-approved parallel redundancy configurations.
The February 2026 commercial specification lists parallel redundancy for a maximum of two UPS units.
Parallel redundancy can improve system availability by allowing suitably configured UPS units to operate together as part of a redundant power architecture.
However, parallel capability depends on compatible UPS hardware, communication interfaces, batteries, protective devices and commissioning procedures.
A separate manufacturer brochure describes a higher parallel-unit limit for the 360V iMAXX range.
Therefore, customers should confirm the exact supported parallel configuration with Microtek before purchasing equipment for a redundant installation.
Parallel operation must never be assumed to work simply by connecting multiple UPS outputs together.
Hot Standby and Cold Start Features
The Microtek iMAXX Series also supports Hot Standby and Cold Start functionality.
Hot Standby allows manufacturer-approved standby arrangements to be considered for installations requiring additional power continuity.
For the 360V models, separate battery banks may be required in the manufacturer’s recommended standby arrangement.
Cold Start supports UPS startup from an appropriately connected and sufficiently charged battery bank when mains power is unavailable.
These functions provide operational flexibility for professional power backup projects.
Hot Standby and parallel redundancy are different arrangements; the correct configuration should be selected according to the installation’s requirements.
Smart LCD Display for Real-Time Monitoring
The Microtek iMAXX 15KVA Online UPS features a smart LCD display designed to provide essential system information.
The display helps operators monitor UPS status, battery conditions, connected electrical loads and fault indications.
Real-time monitoring is useful for IT teams, technical staff and facility managers responsible for essential power equipment.
The UPS also supports RS232, USB and RS485 communication interfaces.
Optional SNMP management can provide additional network-based monitoring where supported.
These interfaces can help integrate the UPS into professional power monitoring arrangements.
Built-In Maintenance Bypass and Static Bypass
The Microtek iMAXX UPS incorporates built-in maintenance bypass and static bypass switching.
These features support approved service and operating arrangements.
The manufacturer specifies zero transfer time from inverter operation to bypass under its documented conditions.
However, bypass operation may expose connected equipment to the quality of the available bypass supply.
Maintenance and bypass operations must be carried out by qualified personnel following Microtek’s safety instructions.
Advanced Electrical and Battery Protection
The Microtek iMAXX 15KVA Series incorporates multiple protection and monitoring features.
These include battery reverse protection, overtemperature indication and protection, and an inbuilt overvoltage cut-off device with surge protection.
Conformal-coated PCB assemblies help provide additional resistance to certain environmental influences.
The manufacturer also describes protection-related features for the inverter and static bypass system during overload conditions.
These technologies contribute to dependable UPS operation when the equipment is correctly installed and maintained.
Generator Compatibility and CVCF Operation
The Microtek 15KVA/360V iMAXX Online UPS supports compatible generator supplies.
Microtek provides a general standby generator sizing guideline of approximately 2.5 times the UPS capacity.
Actual generator requirements depend on connected equipment, battery charging demand and electrical operating characteristics.
The UPS also supports Constant Voltage Constant Frequency (CVCF) operation when an appropriate input supply is available.
CVCF operation without a battery bank does not provide backup energy during a complete power outage.
Professional assessment is recommended when integrating the UPS with a generator or a specialized electrical distribution system.
Floor-Standing Design for Professional Installations
The Microtek iMAXX 15KVA 3:1 UPS uses a substantial floor-standing cabinet designed for commercial power applications.
The manufacturer lists approximate dimensions of 656 × 405 × 817 mm and a net UPS weight of 120kg, excluding external batteries.
The cabinet requires suitable installation space, ventilation and structural support.
The external high-voltage battery bank must be housed appropriately and connected using compatible cables, isolation devices and protective equipment.
Commissioning should be handled by qualified electrical and UPS service personnel.
Suitable for Commercial IT and Infrastructure Applications
The Microtek 15KVA/360V iMAXX Online UPS can be considered for properly sized commercial and institutional installations.
Potential applications include server rooms, networking infrastructure, computing equipment, office IT systems, compatible data-processing equipment and selected electronic control applications.
Its transformer-based design, configurable battery bank and supported redundancy arrangements make it relevant to larger professional power backup projects.
Before purchase, customers should evaluate electrical phases, load capacity, backup runtime, installation conditions and any application-specific compliance requirements.
Buy Microtek 15KVA/360V iMAXX Online UPS from Aadinath Peripherals
At Aadinath Peripherals & Consumables, we supply professional IT hardware, computers, networking equipment, power backup solutions and infrastructure products for businesses and institutions.
Our team assists commercial customers and system integrators with product enquiries, quotations, bulk procurement and equipment requirements.
For official technical information, review the Microtek iMAXX Series technical datasheet.
Customers can also explore the IT hardware and power backup product range available through Aadinath Peripherals.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | Microtek |
| Series | iMAXX |
| Manufacturer Model | iMAXX 15KVA 3:1 / 360V |
| SKU / Part Number | 899-380-0153 |
| UPS Type | Online UPS |
| Technology | DSP-Controlled IGBT Inverter |
| Rated Capacity | 15000VA / 12000W |
| Output Power Factor | 0.8 |
| Input Phase | 3 Phase + Neutral + Ground |
| Output Phase | 1 Phase |
| Nominal Input Voltage | 380 / 400 / 415V AC (3-Phase) |
| Input Voltage Range, Phase to Neutral | 165–280V AC |
| Input Voltage Range, Phase to Phase | 285–485V AC |
| Input Frequency | 50/60Hz ±10% |
| Default Output Voltage | 230V AC |
| Selectable Output Voltage | 208 / 220 / 230V AC |
| Output Voltage Regulation | ±1% |
| Output Waveform | Pure Sine Wave |
| Mains Frequency Synchronization | 50Hz ±1% |
| Battery Mode Frequency | 50Hz ±0.1Hz |
| Crest Factor | 3:1 |
| THD – Linear Load | Less than 2% |
| THD – Non-Linear Load | Less than 5% |
| AC-to-Battery Transfer Time | 0ms |
| Inverter-to-Bypass Transfer Time | 0ms |
| Overload Capability | 110% for 10 min; 150% for 60 sec; 160% for 200ms |
| Static Bypass Overload Capacity | 150% for 1 hour; 180% for 30 sec; above 200% for 200ms |
| AC Mode Efficiency | Greater than 88% |
| Battery Mode Efficiency | 90% |
| Default Battery Voltage | 360V DC |
| Adjustable Battery Voltage | 348–384V DC |
| Default Battery Configuration | 30 × 12V External Batteries |
| Adjustable Battery Number | 29 / 30 / 31 / 32 |
| Battery Type | Compatible Lead-Acid / Tubular / SMF |
| Inbuilt Charger Capacity | 20A |
| Charging Current | 5A default per older datasheet; actual maximum depends on operating conditions |
| Isolation Transformer | Built-In at Output |
| Display | Smart LCD |
| Parallel Redundancy | 2 Units per February 2026 price list; higher count requires confirmation |
| Hot Standby | Supported |
| Cold Start | Supported |
| Battery Reverse Protection | Yes |
| Maintenance Bypass | Built-In |
| Static Bypass | Built-In |
| Overtemperature Protection | Yes |
| Overvoltage / Surge Protection | Yes |
| Conformal-Coated PCBs | Yes |
| CVCF Operation | Supported with valid input power |
| Generator Compatibility | Yes |
| Communication | RS232 / USB / RS485 |
| Optional Monitoring | SNMP |
| Dimensions (L × W × H) | 656 × 405 × 817 mm |
| Net Weight | 120kg, excluding batteries |
| Operating Humidity | 0–90% RH, Non-Condensing |
| Noise Level | Less than 60dBA at 1m |
| Warranty | 2 Years per February 2026 price list; confirm current manufacturer terms |