Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS

₹246,000

The Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS (899-380-0203) is a professional transformer-based power backup system designed for critical IT infrastructure, commercial facilities, server rooms and compatible electronic equipment.

Featuring 20KVA/16000W capacity, DSP-controlled IGBT inverter technology, a 0.8 output power factor, an inbuilt output isolation transformer and a 20A inbuilt charger, this Online UPS delivers dependable pure sine wave output with a three-phase input and single-phase output configuration.

Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS – Advanced Transformer-Based Power Backup

The Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS is a high-capacity uninterruptible power supply designed for critical IT infrastructure, commercial establishments, server rooms and compatible professional electronic equipment. Featuring advanced Digital Signal Processing (DSP) technology, an IGBT-based inverter, an inbuilt output isolation transformer and a 0.8 output power factor, this UPS provides dependable power protection for demanding business environments.

With a rated capacity of 20000VA/16000W, a 360V DC external battery system, a 20A inbuilt charger and an intelligent monitoring interface, the Microtek iMAXX Series combines power conversion technology with flexible battery options and supported redundancy features.

Developed by Microtek, this Online UPS uses a three-phase input and single-phase output (3:1) configuration, making it suitable for appropriately designed commercial electrical installations.

Advanced DSP Technology with IGBT-Based Inverter

The Microtek 20KVA iMAXX Online UPS uses Digital Signal Processing technology with an IGBT-based inverter to manage electrical power conversion and output regulation.

Unlike a conventional standby UPS, an Online UPS continuously delivers regulated power through its inverter during normal operating conditions.

The incoming electrical supply is processed before power reaches connected equipment, helping reduce the impact of many electrical disturbances.

When mains electricity fails, the external battery bank supplies energy to the inverter without a normal transfer delay.

Microtek specifies zero AC-to-battery transfer time during supported online operation.

This helps maintain power continuity for compatible electronic equipment during unexpected interruptions.

Three-Phase Input and Single-Phase Output

The Microtek 20KVA/360V iMAXX Online UPS is designed for three-phase electrical input and single-phase output.

Its nominal input supply is specified as 380V, 400V or 415V AC across three phases, with the appropriate neutral and earthing arrangement.

The UPS delivers a regulated single-phase AC output, with 230V as the default output voltage.

Supported selectable output voltages include 208V, 220V and 230V AC.

This configuration is relevant to offices, commercial buildings and institutional facilities where three-phase electricity is available, but critical equipment requires protected single-phase power.

It must not be confused with the Microtek iMAXX 20KVA three-phase output version, which uses a different manufacturer part number.

Electrical installation and load distribution should be designed by a qualified professional.

20KVA/16000W Output with 0.8 Power Factor

The Microtek iMAXX 20KVA Online UPS provides a rated output capacity of 20KVA/16KW.

Its 0.8 output power factor gives the system a rated active power capacity of 16000 watts.

This makes the UPS suitable for properly sized professional computing equipment, networking infrastructure, compatible server systems and commercial electronics.

Before selecting a high-capacity UPS, organizations should calculate the combined continuous power requirements of connected equipment.

The load assessment should include startup current, operating peaks, electrical characteristics and suitable headroom.

Correct UPS sizing reduces the risk of overloading and helps improve the reliability of business-critical electrical installations.

Inbuilt Output Isolation Transformer

One of the key features of the Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS is its inbuilt output isolation transformer.

The transformer provides galvanic isolation within the supported output configuration, offering electrical separation between the relevant power circuits.

This can help reduce certain types of common-mode electrical noise and interference.

Transformer-based UPS systems are often considered for professional installations where isolation is an important electrical design requirement.

The Microtek iMAXX model integrates the output transformer inside the UPS cabinet.

However, isolation does not eliminate the need for proper grounding, protective devices, electrical safety procedures or equipment-specific compatibility checks.

360V DC External Battery System

The Microtek 20KVA iMAXX Online UPS uses an external high-voltage battery system.

The default configuration requires 30 compatible 12V batteries connected in series, forming a nominal 360V DC battery bank.

The commercial product details also specify supported 31-battery and 32-battery configurations.

According to the manufacturer’s technical brochure, the 360V iMAXX range additionally supports a 29-battery setting under the appropriate configuration.

These battery quantities correspond to different nominal DC voltages and must only be used after the UPS settings have been correctly configured.

The manufacturer identifies lead-acid, tubular and sealed maintenance-free batteries as suitable battery categories, subject to approved specifications.

Actual backup duration depends on battery capacity, connected load, battery health, UPS efficiency and environmental conditions.

The UPS itself does not contain the external battery bank as standard.

Battery Voltage Configuration and Backup Planning

External battery selection is an important part of the complete UPS installation.

For the default 30-battery configuration, the nominal battery voltage is 360V DC.

A supported 31-battery arrangement provides 372V DC, while a 32-battery arrangement provides 384V DC.

Any change in battery quantity requires the correct manufacturer-supported charger settings and appropriate protection equipment.

Customers requiring longer backup should select a compatible battery capacity after calculating their actual electrical load and required runtime.

The battery rack, DC circuit breaker, interconnecting cables and other protection accessories should be considered during procurement.

Because the system operates at hazardous DC voltages, battery installation must be performed by qualified personnel.

20 Amp Inbuilt Battery Charger

The Microtek iMAXX 20KVA Online UPS incorporates a 20 Amp inbuilt charger.

This provides charging capability for properly configured external battery systems.

The manufacturer’s older technical datasheet lists a default charging-current setting of 5A.

The actual available charging current depends on battery voltage, UPS load and the approved system configuration.

This distinction is important because a charger rated at 20A does not necessarily deliver 20A continuously under all operating conditions.

Charging settings should be selected according to the installed batteries and Microtek’s technical guidance.

Correct charging configuration helps maintain battery readiness and supports dependable backup operation.

Pure Sine Wave Output with Stable Voltage Regulation

The Microtek 20KVA/360V iMAXX Online UPS provides pure sine wave output during battery mode.

Pure sine wave output supports stable electrical operation for many compatible professional electronic systems and power supplies.

The manufacturer specifies an output voltage regulation of approximately ±1%.

It also lists total harmonic distortion limits of less than 2% for linear loads and less than 5% for non-linear loads.

The output frequency can be synchronized with the incoming mains supply or controlled in battery operation according to the specified settings.

These characteristics support dependable power quality for appropriately connected equipment.

Parallel Redundancy for Critical Power Systems

The Microtek 20KVA/360V iMAXX Online UPS supports manufacturer-approved parallel redundancy.

The commercial specification effective February 2026 lists a maximum two-unit parallel redundancy configuration.

Parallel redundancy allows compatible UPS units to be installed in an approved power architecture to improve system availability.

This can be useful for organizations seeking additional protection against an individual UPS unit failure.

Parallel installations require correct synchronization, compatible communication hardware, approved wiring and appropriate battery-bank arrangements.

A separate June 2025 manufacturer brochure describes a maximum three-unit configuration for the 15KVA and 20KVA 3:1 models.

Therefore, the exact supported unit count must be confirmed against the supplied hardware and firmware revision.

Hot Standby and Cold Start Functionality

The Microtek iMAXX Series includes Hot Standby and Cold Start functions.

Hot Standby supports approved standby arrangements where a compatible additional UPS can serve as backup.

For 360V iMAXX models, the manufacturer’s updated brochure describes separate battery-bank requirements for supported standby arrangements.

Cold Start permits UPS startup from a correctly connected and sufficiently charged battery bank under supported conditions.

These features provide additional flexibility for professional power backup installations.

Hot Standby and parallel redundancy are not identical operating configurations, so the required system design should be confirmed before commissioning.

Smart LCD Display and Power Monitoring

The Microtek iMAXX 20KVA Online UPS comes with a smart LCD display designed to provide real-time operating information.

The display helps users monitor electrical conditions, system status and fault indications.

These features are especially useful for IT teams, facility managers and technicians responsible for maintaining critical power infrastructure.

The UPS supports RS232, USB and RS485 communication interfaces.

Optional SNMP network management is available for suitable monitoring systems.

This allows organizations to consider centralized UPS supervision as part of their broader IT infrastructure management.

Built-In Maintenance Bypass and Static Bypass

The Microtek iMAXX 20KVA UPS incorporates both maintenance bypass and static bypass functions.

These features support approved service arrangements and power transfer under specified conditions.

The manufacturer specifies zero transfer time from inverter operation to static bypass in its documented operating conditions.

Bypass operation should be used only according to Microtek’s instructions because the connected equipment may then receive the available bypass supply directly.

Maintenance and electrical switching should be handled by qualified personnel.

Advanced Electrical Protection Features

The Microtek iMAXX Online UPS includes several protection technologies intended to improve system reliability.

These include overvoltage cut-off with surge protection, battery reverse-polarity protection and overtemperature indication and protection.

The UPS also features conformal-coated PCB assemblies, which can provide additional protection from some environmental influences.

The manufacturer specifies overload handling and static bypass overload capabilities under defined conditions.

Correct installation, ventilation, electrical earthing and periodic maintenance remain essential for reliable operation.

Generator Compatibility and CVCF Operation

The Microtek 20KVA/360V iMAXX Online UPS is compatible with suitably specified generator supplies.

Microtek recommends a standby generator capacity of approximately 2.5 times the UPS rating as a general sizing guideline.

Actual generator requirements depend on the electrical load, charging demand and generator operating characteristics.

The UPS also supports Constant Voltage Constant Frequency (CVCF) operation when appropriate input power is available.

CVCF operation without a battery bank should not be confused with battery backup, because the UPS cannot provide stored-energy support during a complete mains outage without batteries.

Applications for Offices, Data Centers and Commercial Facilities

The Microtek 20KVA/360V iMAXX 3-Phase Input Online UPS is suitable for professionally designed installations requiring reliable protected single-phase power.

Potential applications include server rooms, networking infrastructure, commercial computing equipment, corporate office systems, compatible data-processing equipment and technical electronic systems.

The transformer-based design and supported redundancy options make it relevant to larger institutional and commercial power backup projects.

Before procurement, customers should evaluate the connected load, electrical phase arrangement, battery capacity, backup runtime and installation requirements.

Floor-Standing Cabinet and Professional Installation

The Microtek iMAXX 20KVA UPS uses a substantial floor-standing cabinet.

The manufacturer’s technical brochure lists approximate dimensions of 656 × 405 × 817 mm and a net UPS weight of 145kg, excluding external batteries.

Appropriate installation space, cabinet support, cooling clearance and electrical access should be provided.

The external battery bank requires its own suitable installation arrangement, including compatible DC protection and interconnections.

Professional installation is necessary because of the high electrical capacity and hazardous battery-bank voltage.

Buy Microtek 20KVA/360V iMAXX Online UPS from Aadinath Peripherals

At Aadinath Peripherals & Consumables, we supply professional IT hardware, UPS power backup systems, computers, networking equipment and infrastructure solutions for businesses and institutions.

We assist corporate offices, system integrators and institutional customers with product enquiries, quotations and bulk procurement requirements.

For detailed manufacturer specifications, review the Microtek iMAXX Series technical datasheet.

You can also explore our IT hardware and power backup product range for additional equipment and business procurement needs.

Technical Specifications

Specification Details
Brand Microtek
Series iMAXX
Manufacturer Model iMAXX 20KVA (3:1)
Part Number / SKU 899-380-0203
UPS Type Online UPS
Technology DSP-Controlled IGBT Inverter
Rated Capacity 20000VA / 16000W
Output Power Factor 0.8
Input Phase Three Phase + Neutral + Ground
Output Phase Single Phase
Nominal Input Voltage 380 / 400 / 415V AC (3 Phase)
Input Range (Phase to Neutral) 165–280V AC
Input Range (Phase to Phase) 285–485V AC
Input Frequency 50Hz / 60Hz ±10%
Default Output Voltage 230V AC
Selectable Output Voltage 208 / 220 / 230V AC
Output Voltage Regulation ±1%
Output Waveform Pure Sine Wave
Synchronized Mains Frequency 50Hz ±1%
Battery Mode Frequency 50Hz ±0.1Hz
Crest Factor 3:1
THD – Linear Load Less than 2%
THD – Non-Linear Load Less than 5%
Normal AC-to-Battery Transfer 0ms
Inverter-to-Bypass Transfer 0ms
Overload Capacity 110% for 10 min; 150% for 60 sec; above 160% for 200ms
Static Bypass Overload 150% for 1 hour; 180% for 30 sec; above 200% for 200ms
AC Mode Efficiency Greater than 88%
Battery Mode Efficiency 90%
Default Battery Voltage 360V DC
Adjustable Battery Voltage 348–384V DC
Default Battery Quantity 30 × 12V External Batteries
Adjustable Battery Quantity 29 / 30 / 31 / 32
Battery Type Compatible Lead-Acid / Tubular / SMF
Inbuilt Charger Capability 20A
Default Charging Current 5A per technical datasheet
Charging Configuration Dependent on load, battery voltage and approved settings
Isolation Transformer Built-In at Output
Display Smart LCD
Parallel Redundancy Maximum 2 Units per February 2026 listing; confirm revision
Hot Standby Yes
Cold Start Yes
Battery Reverse Protection Yes
Maintenance Bypass Built-In
Static Bypass Built-In
Overtemperature Protection Yes
Overvoltage / Surge Protection Yes
Conformal-Coated PCB Yes
CVCF Operation Supported with valid input supply
Generator Compatibility Yes
Communication RS232 / USB / RS485
Optional Monitoring SNMP
Dimensions (L × W × H) 656 × 405 × 817 mm
Net Weight 145kg, excluding batteries
Operating Temperature 0–55°C
Operating Humidity 0–90% RH, Non-Condensing
Noise Level Less than 60dBA at 1m
Warranty 2 Years per February 2026 price list; confirm terms
0 reviews
0
0
0
0
0

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.