Microtek SuperMax 10KVA/240V Configurable Online UPS

₹158,000

The Microtek SuperMax 10KVA/240V Configurable Online UPS (899-430-1002) is a high-performance power backup system designed for professional IT infrastructure, commercial installations and compatible electronic equipment.

Featuring 10KVA/10000W capacity, unity (1.0) output power factor, high-frequency true double-conversion technology and a 12A inbuilt battery charger, this UPS delivers pure sine wave power for applications requiring dependable power continuity.

SKU: 899-430-1002 Categories: ,

Product Enquiry

Interested in this product? Fill out the form below.

    Microtek SuperMax 10KVA Online UPS – Configurable 3-Phase Power Backup Solution

    The Microtek SuperMax 10KVA Online UPS (899-430-1002) is a professional, high-frequency uninterruptible power supply designed to deliver dependable electrical protection for commercial offices, IT infrastructure, networking installations and compatible industrial electronic systems.

    Featuring 10KVA/10000W rated capacity, a unity output power factor, advanced true double-conversion technology and a 12A inbuilt battery charger, this UPS combines high power capacity with configurable electrical phase operation.

    The system uses a ±120V DC external battery arrangement consisting of 20 compatible 12V batteries and supports standard three-phase input and three-phase output operation.

    A key advantage of this model is its ability to support approved alternative input and output arrangements, including single-phase input/single-phase output (1:1) and three-phase input/single-phase output (3:1).

    Manufactured by Microtek, the SuperMax UPS is suitable for professional installations where power quality, battery backup and flexible electrical distribution are important.

    True Double-Conversion Online UPS Technology

    The Microtek SuperMax 10KVA Online UPS operates using true double-conversion technology.

    In a double-conversion UPS, incoming AC power is processed through the UPS conversion system before regulated power is delivered to the connected load.

    During normal operation, the inverter continuously supplies the protected equipment.

    This arrangement helps reduce the impact of many common mains power disturbances, including voltage fluctuations and unexpected power interruptions.

    When the incoming power supply fails, the external battery bank continues supplying energy to the inverter.

    The model’s published specifications identify zero normal AC-to-battery transfer time.

    This is important for compatible electronic equipment that may be affected by even short interruptions in its electrical supply.

    10KVA/10000W Capacity with Unity Power Factor

    The Microtek SuperMax 10KVA Online UPS provides 10000VA/10000W rated output capacity.

    Its unity (1.0) output power factor means that the rated active power equals the rated apparent power under the specified operating conditions.

    This provides a higher rated wattage than a conventional 10KVA UPS with a 0.8 output power factor, which is rated at 8000W.

    The increased active-power rating makes the SuperMax model suitable for properly sized workstations, business computing infrastructure, networking systems and compatible commercial electronics.

    Before installation, customers should calculate the connected equipment’s total continuous and peak power requirements.

    Adequate headroom should be maintained, especially when the load contains equipment with unusual startup or operating characteristics.

    Three-Phase Input and Three-Phase Output

    The standard operating arrangement for the Microtek SuperMax 10KVA/240V Online UPS is three-phase input and three-phase output.

    This is commonly described as a 3:3 UPS configuration.

    It is intended for locations with a suitable three-phase electrical supply and connected equipment requiring regulated three-phase power.

    The detailed supplier specifications list nominal three-phase output voltage settings including 380V, 400V and 415V AC.

    The actual supported input and output settings must be configured according to the supplied UPS hardware and approved operating mode.

    Professional commissioning is essential because the arrangement involves three-phase electrical distribution.

    Configurable Single-Phase Input and Output

    One important advantage of this model is its configurable phase operation.

    In addition to standard 3:3 mode, the February 2026 commercial specification identifies support for single-phase input and single-phase output (1:1).

    This provides flexibility for approved installations where a three-phase supply may not be used.

    However, phase reconfiguration is not a simple plug-and-play setting.

    Electrical terminals, wiring, protection, rated output capacity and available modes must be confirmed with Microtek before commissioning.

    The customer should select the intended operating mode before installation and communicate it during the quotation process.

    Configurable Three-Phase Input and Single-Phase Output

    The Microtek SuperMax 10KVA Online UPS also supports three-phase input and single-phase output (3:1) under the listed configurable arrangements.

    This can be relevant to commercial buildings that have a three-phase input supply but require protected single-phase output for compatible equipment.

    The manufacturer-approved conversion procedure must be followed.

    Output power limitations, phase balance requirements and electrical connections may differ from the standard 3:3 operating mode.

    These details should be confirmed before advertising the same output capacity across every phase configuration.

    ±120V DC External Battery System

    The Microtek SuperMax 10KVA Online UPS operates with a split-voltage external battery system rated at ±120V DC.

    The supplied product configuration specifies 20 compatible batteries.

    Using twenty nominal 12V batteries, the complete arrangement has approximately 240V between its positive and negative DC rails.

    The split configuration involves two nominal 120V sections, which must be connected according to the UPS manufacturer’s electrical diagram.

    This is an important distinction from UPS models using a conventional single-polarity 240V DC battery connection.

    The required battery wiring, polarity, midpoint and protection must be confirmed before connecting the batteries.

    20 External Batteries for Flexible Backup Planning

    The default battery arrangement uses 20 compatible external 12V batteries.

    The battery capacity in ampere-hours should be selected according to the connected electrical load and required backup duration.

    The system is generally associated with approved VRLA or lead-acid battery installations.

    Customers may require additional equipment such as battery racks, interconnecting cables, suitable DC protection and battery disconnect arrangements.

    Actual backup duration depends on the battery capacity, battery condition, load, environmental temperature and UPS conversion efficiency.

    Backup runtime should not be estimated solely from the 10KVA rating.

    A proper battery-sizing calculation should be completed for each installation.

    Powerful 12 Amp Inbuilt Charger

    The Microtek SuperMax 10KVA Online UPS features a 12 Amp maximum inbuilt battery charger.

    The detailed 10KVA supplier specifications describe configurable charging currents from 1A through 12A, with a default setting of 4A.

    Adjustable charging allows the charger to be configured for a compatible external battery bank.

    The appropriate current must be selected based on battery capacity and manufacturer specifications.

    The maximum 12A rating should not automatically be used with every battery installation.

    Correct charging settings are important for maintaining dependable backup availability and battery service life.

    Pure Sine Wave Power Output

    The Microtek SuperMax 10KVA UPS delivers pure sine wave output during battery operation.

    Pure sine wave power is appropriate for many compatible computing devices and professional electronic systems.

    The detailed supplier specifications identify approximately ±1% output voltage regulation in battery mode.

    They also specify low harmonic distortion under supported linear and non-linear load conditions.

    These characteristics support consistent output power quality when the UPS is correctly installed and operated within its rated limits.

    DSP Technology and Active Power Factor Correction

    The UPS uses DSP-based control technology to monitor and regulate power conversion.

    DSP control supports efficient electrical processing and system management.

    Published product information also identifies active power factor correction for the input supply.

    This feature is designed to improve the electrical characteristics of the power drawn from the incoming supply under supported conditions.

    The input power factor should not be confused with the UPS’s 1.0 output power factor.

    ECO Mode for Improved Energy Efficiency

    The Microtek SuperMax 10KVA Online UPS supports ECO mode operation.

    ECO mode can reduce electrical conversion losses when the incoming power source meets the required operating conditions.

    Detailed supplier technical information lists efficiency figures of approximately 95.5% in AC mode, 98.5% in ECO mode and 94.5% in battery mode.

    Actual efficiency depends on the operating mode, electrical load and manufacturer-defined test conditions.

    ECO mode should be selected carefully for applications requiring continuous double-conversion power conditioning, because its operating behaviour differs from the standard online inverter path.

    Emergency Power Off Function

    The SuperMax UPS supports an Emergency Power Off (EPO) feature.

    EPO can be incorporated into an appropriate electrical safety arrangement when supported by the installation design.

    This feature allows authorized personnel or connected safety systems to initiate the specified emergency power shutdown procedure.

    The EPO circuit, wiring and operating logic should be configured according to Microtek’s instructions.

    EPO functionality is not a substitute for appropriate circuit breakers, grounding or other required electrical safety measures.

    Generator Compatibility

    The Microtek SuperMax 10KVA Online UPS is generator compatible within its electrical operating requirements.

    This makes it relevant to installations where a suitably rated generator is used during extended mains failures.

    Generator sizing should consider the connected electrical load, battery charging requirements and the generator’s voltage and frequency stability.

    The UPS should be operated only with a generator whose output meets the approved input specifications.

    LCD Display and UPS Monitoring

    The UPS incorporates an LCD display for monitoring operating conditions.

    The display provides information about system status, load, battery level, input and output voltage, discharge information and fault conditions.

    This helps technical personnel monitor backup performance and identify potential issues.

    The model also provides supported communication interfaces for UPS monitoring.

    RS232 and USB communication are described in supplier documentation, while SNMP is available as an optional management feature.

    These functions can be useful for professional installations where monitoring and maintenance are important.

    Maintenance Bypass and Optional Parallel Operation

    The Microtek SuperMax 10KVA UPS supports maintenance bypass functionality.

    This allows compatible maintenance procedures to be carried out under the manufacturer’s approved operating arrangement.

    The model’s supplier documentation also mentions optional parallel operation.

    However, the exact maximum number of parallel UPS units is not stated in the February 2026 specification for this SKU.

    Customers requiring a parallel installation should confirm the compatible hardware, accessories, supported battery architecture and maximum unit count directly with Microtek.

    Parallel capability should not be assumed to provide unrestricted additional capacity without an approved system design.

    Protection Features for Professional Applications

    The Microtek SuperMax Series includes UPS operating alarms and protection features.

    These include supported overload protection, temperature-related warnings, battery-low alerts and fault indications.

    The detailed supplier specifications also list defined overload handling capabilities in AC and battery operation.

    These features help technicians recognize abnormal operating conditions.

    Correct circuit protection, grounding, ventilation and maintenance remain essential for safe and reliable operation.

    Compact Tower Design

    The Microtek SuperMax 10KVA UPS uses a professional floor-standing cabinet.

    Detailed supplier listings identify approximate cabinet dimensions of 630 × 250 × 750 mm and a net UPS weight of approximately 28kg, excluding external batteries.

    These measurements should be confirmed against the exact supplied revision before arranging transportation or preparing the installation location.

    The external battery system requires separate installation space and appropriately rated protection devices.

    Suitable for Commercial IT and Critical Electronic Equipment

    The Microtek SuperMax 10KVA Online UPS is suitable for professional installations requiring dependable backup power.

    Potential applications include compatible server equipment, commercial computers, workstations, routers, network switches, office electronic systems and selected technical equipment.

    The ability to configure different phase arrangements offers flexibility for a variety of properly designed installations.

    However, applications involving large motors, regenerative loads or specialized industrial machinery should be evaluated individually before connection.

    The complete power backup system should be specified according to the electrical load, required runtime and safety requirements.

    Buy Microtek SuperMax 10KVA Online UPS from Aadinath Peripherals

    At Aadinath Peripherals & Consumables, we supply IT hardware, computers, networking equipment, UPS power backup systems and infrastructure products for businesses and institutions.

    Our team assists commercial customers, IT professionals and procurement teams with UPS enquiries, compatible battery requirements and bulk quotations.

    For brand information, visit the official Microtek website.

    Customers can also explore the IT hardware and power backup solutions available through Aadinath Peripherals.

    For pricing, stock availability, battery configuration and bulk procurement enquiries, email sales@aadinathperipherals.com or call +91 90760 00285.

    Choose the Microtek SuperMax 10KVA/240V Configurable Online UPS (899-430-1002) for 10000W output capacity, unity power factor, true double-conversion technology, 12A charging, a 20-battery split DC system and support for multiple approved input/output phase configurations.

    Technical Specifications

    Specification Details
    Brand Microtek
    Series SuperMax
    Model 10KVA Configurable Phase Online UPS
    Manufacturer SKU 899-430-1002
    UPS Type Online UPS
    Technology High-Frequency True Double Conversion
    Rated Capacity 10000VA / 10000W
    Output Power Factor 1.0 (Unity)
    Standard Input / Output 3 Phase / 3 Phase
    Alternate Mode 1 1 Phase / 1 Phase
    Alternate Mode 2 3 Phase / 1 Phase
    Nominal 3-Phase Input 3 × 400V AC
    Nominal 3-Phase Output 3 × 380 / 400 / 415V AC, per supplier specification
    Additional Output Setting 3 × 360V AC, subject to applicable derating and confirmation
    Input Frequency 46–54Hz or 56–64Hz
    Input Power Factor Greater than 0.99 at full load, per supplier
    Battery Mode Voltage Regulation ±1%
    Battery Mode Frequency 50Hz ±0.1Hz / 60Hz ±0.1Hz
    Output Waveform Pure Sine Wave
    Current Crest Ratio 3:1 Maximum
    Output THD – Linear Load Less than 2%
    Output THD – Non-Linear Load Less than 5%
    AC-to-Battery Transfer 0ms
    Inverter-to-Bypass Transfer 0ms when synchronized; otherwise interruption possible
    AC Mode Efficiency 95.5%, supplier-listed
    ECO Mode Efficiency 98.5%, supplier-listed
    Battery Mode Efficiency 94.5%, supplier-listed
    Battery Voltage ±120V DC
    Total Nominal Battery Voltage 240V between DC rails
    Battery Configuration Two nominal 120V sections with midpoint
    Battery Quantity 20 × 12V External Batteries
    Battery Type Compatible VRLA / Lead-Acid
    Maximum Charger 12A
    Adjustable Charging Current 1A–12A in 1A steps, supplier-listed
    Default Charging Current 4A, supplier-listed
    Display LCD
    ECO Mode Yes
    Frequency Converter Mode Yes
    EPO Supported
    Generator Compatible Yes
    Maintenance Bypass Available
    Optional Parallel Operation Supplier-listed; maximum unit count unverified
    Communication RS232 / USB
    Optional SNMP Yes
    Dimensions (D × W × H) 630 × 250 × 750 mm, supplier-listed
    Net UPS Weight 28kg, supplier-listed
    Operating Temperature 0–50°C, supplier-listed
    Humidity Up to 95% RH, non-condensing
    Noise Level Less than 58dB at 1m, supplier-listed
    Warranty 2 Years in February 2026 price list; verify terms

     